Why do buildings fall in earthquakes? – Vicki V. May

Earthquakes have always been a terrifying phenomenon,
and they’ve become more deadly as our cities have grown,
with collapsing buildings posing one of the largest risks.
Why do buildings collapse in an earthquake,
and how can it be prevented?
If you’ve watched a lot of disaster films,
you might have the idea
that building collapse is caused directly by the ground beneath them
shaking violently, or even splitting apart.
But that’s not really how it works.
For one thing, most buildings are not located right on a fault line,
and the shifting tectonic plates go much deeper than building foundations.
So what’s actually going on?
In fact, the reality of earthquakes and their effect on buildings
is a bit more complicated.
To make sense of it, architects and engineers use models,
like a two-dimensional array of lines representing columns and beams,
or a single line lollipop with circles representing the building’s mass.
Even when simplified to this degree, these models can be quite useful,
as predicting a building’s response to an earthquake
is primarily a matter of physics.
Most collapses that occur during earthquakes
aren’t actually caused by the earthquake itself.
Instead, when the ground moves beneath a building,
it displaces the foundation and lower levels,
sending shock waves through the rest of the structure
and causing it to vibrate back and forth.
The strength of this oscillation depends on two main factors:
the building’s mass, which is concentrated at the bottom,
and its stiffness,
which is the force required to cause a certain amount of displacement.
Along with the building’s material type and the shape of its columns,
stiffness is largely a matter of height.
Shorter buildings tend to be stiffer and shift less,
while taller buildings are more flexible.
You might think that the solution is to build shorter buildlings
so that they shift as little as possible.
But the 1985 Mexico City earthquake is a good example of why that’s not the case.
During the quake,
many buildings between six and fifteen stories tall collapsed.
What’s strange is that while shorter buildings nearby did keep standing,
buildings taller than fifteen stories were also less damaged,
and the midsized buildings that collapsed
were observed shaking far more violently than the earthquake itself.
How is that possible?
The answer has to do with something known as natural frequency.
In an oscillating system,
the frequency is how many back and forth movement cycles occur within a second.
This is the inverse of the period,
which is how many seconds it takes to complete one cycle.
And a building’s natural frequency, determined by its mass and stiffness,
is the frequency that its vibrations will tend to cluster around.
Increasing a building’s mass slows down the rate at which it naturally vibrates,
while increasing stiffness makes it vibrate faster.
So in the equation representing their relationship,
stiffness and natural frequency are proportional to one another,
while mass and natural frequency are inversely proportional.
What happened in Mexico City was an effect called resonance,
where the frequency of the earthquake’s seismic waves
happen to match the natural frequency of the midsized buildings.
Like a well-timed push on a swingset,
each additional seismic wave amplified the building’s vibration
in its current direction,
causing it to swing even further back, and so on,
eventually reaching a far greater extent than the initial displacement.
Today, engineers work with geologists and seismologists
to predict the frequency of earthquake motions at building sites
in order to prevent resonance-induced collapses,
taking into account factors such as soil type and fault type,
as well as data from previous quakes.
Low frequencies of motion will cause more damage to taller
and more flexible buildings,
while high frequencies of motion pose more threat
to structures that are shorter and stiffer.
Engineers have also devised ways to abosrb shocks
and limit deformation using innovative systems.
Base isolation uses flexible layers
to isolate the foundation’s displacement from the rest of the building,
while tuned mass damper systems cancel out resonance
by oscillating out of phase with the natural frequency
to reduce vibrations.
In the end, it’s not the sturdiest buildings that will remain standing
but the smartest ones.
0 views

답글 남기기

이메일 주소는 공개되지 않습니다. 필수 필드는 *로 표시됩니다

Shopping Cart
/study-room/
http://pf.kakao.com/_xeAFxdG
https://talkya.co.kr/video-category/
https://www.readingn.com/?utm_source=naver_bspc&utm_medium=banner&utm_campaign=homepage_landing&n_media=27758&n_query=%EB%A6%AC%EB%94%A9%EC%95%A4&n_rank=1&n_ad_group=grp-a001-04-000000018019355&n_ad=nad-a001-04-000000266292918&n_keyword_id=nkw-a001-04-000003255044813&n_keyword=%EB%A6%AC%EB%94%A9%EC%95%A4&n_campaign_type=4&n_contract=tct-a001-04-000000000757110&n_ad_group_type=5&NaPm=ct%3Dlnju29co%7Cci%3D0z00002lPgfz397IXfl2%7Ctr%3Dbrnd%7Chk%3Dd0f544a47fd94ae9a321e278152b228f765250ec
https://blog.naver.com/brainfinder